Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Medical Sciences Journal ; (4): 213-219, 2013.
Article in English | WPRIM | ID: wpr-243234

ABSTRACT

Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.


Subject(s)
Humans , Coronary Angiography , Coronary Stenosis , Electrocardiography , Heart Rate , Radiation Dosage
2.
Chinese Medical Sciences Journal ; (4): 225-231, 2013.
Article in English | WPRIM | ID: wpr-243232

ABSTRACT

Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv, P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.


Subject(s)
Humans , Coronary Angiography , Electrocardiography , Radiation Dosage , Tomography, X-Ray Computed
3.
Chinese Journal of Pathology ; (12): 529-535, 2008.
Article in Chinese | WPRIM | ID: wpr-315134

ABSTRACT

<p><b>OBJECTIVE</b>To study the expression of stromal cell derived factor 1(SDF-1)/CXCR4 and their association with clinicopathologic features and lymph node metastasis in invasive breast carcinoma.</p><p><b>METHODS</b>The expression of SDF-1 was studied by immunohistochemistry and in-situ hybridization. Immunohistochemical study for CXCR4 was also performed. The correlation with various clinicopathologic parameters was analyzed.</p><p><b>RESULTS</b>(1) SDF-1 was mainly expressed in tumor cells and the level of its expression (both membranous and cytoplasmic) in lymph node-positive group was higher than that in lymph node-negative group (P = 0.033). Only cytoplasmic expression correlated with the number of positive lymph node involved by metastasis, TNM tumor stage, histologic grade, tumor dimension and estrogen receptor status (P < 0.05). (2) SDF-1 protein was also detected in the endothelial cells, although its mRNA was rarely detected. SDF-1 staining in lymphatics was associated with positive lymph node (P = 0.005) and SDF-1 staining in blood vessels correlated with stromal lymphocytic reaction (P = 0.001). The extent of nodal involvement was higher in the group with positive SDF-1 staining in blood vessels and with prominent lymphocytic reaction than that in other groups with one or neither of the two features (P < 0.05). (3) On the other hand, CXCR4 was mainly expressed in tumor cells (both nuclear and cytoplasmic); and the level of its expression in lymph node-positive group was higher than that in lymph node-negative group (P = 0.005). Only cytoplasmic expression correlated with the number of positive lymph node involved by metastasis, TNM tumor stage, histologic grade, tumor dimension and HER2 status (P < 0.05). The nuclear expression of CXCR4 was only correlated with progesterone receptor status (P < 0.01). The cytoplasmic expression CXCR4 also positively correlated with SDF-1 expression (P = 0.001).</p><p><b>CONCLUSIONS</b>SDF-1 and CXCR4 can serve as biomarkers for diagnosis and prediction of lymph node metastasis, as well as potential therapeutic targets in invasive breast carcinoma. The difference in localization and staining patterns may also carry different significance.</p>


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Breast Neoplasms , Genetics , Metabolism , Pathology , Chemokine CXCL12 , Genetics , Metabolism , Chemokines, CXC , Metabolism , Immunohistochemistry , Lymph Nodes , Pathology , Lymphatic Metastasis , Pathology , Receptor, ErbB-2 , Genetics , Metabolism , Receptors, CXCR4 , Genetics , Metabolism
4.
Chinese Journal of Pathology ; (12): 599-603, 2008.
Article in Chinese | WPRIM | ID: wpr-315095

ABSTRACT

<p><b>OBJECTIVE</b>To study the significance of interleukin-1beta (IL-1beta) expression and microvascular density (MVD) in invasive micropapillary carcinoma (IMPC) of breast.</p><p><b>METHODS</b>Immunohistochemical study for IL-1beta and CD34 was performed on 100 cases of IMPC and 97 cases of invasive ductal carcinoma (IDC). The relationship between IL-1beta expression, MVD and various pathologic parameters (estrogen and progesterone receptor status, Ki-67 proliferative index, histologic grade and lymph node metastasis) in IMPC was analyzed.</p><p><b>RESULTS</b>There was no significant difference in expression of IL-1beta between IMPC and IDC (P = 0.924). The expression of IL-1beta positively correlated with proliferative index (P = 0.023), histologic grade (P = 0.038) and lymph node metastasis (P = 0.008), and negatively correlated with estrogen receptor expression (P = 0.035). The MVD in IMPC was significantly higher than that in IDC (66.4 versus 60.0, P = 0.003). The mean MVD in node-positive IMPC was higher than that in node-negative IMPC (68.8 versus 54.4, P = 0.001). In IMPC, the MVD in histologic grade II and III tumors was much higher than that in histologic grade I tumors (68.3 versus 59.9, P = 0.025). It had no relationship with hormonal receptor status and proliferative index.</p><p><b>CONCLUSION</b>Overexpression of IL-1beta and high microvessel density may have important roles in tumor cell proliferation and lymph node metastasis in IMPC.</p>


Subject(s)
Female , Humans , Middle Aged , Breast Neoplasms , Metabolism , Pathology , Carcinoma , Pathology , Carcinoma, Ductal, Breast , Pathology , Carcinoma, Papillary , Metabolism , Interleukin-1beta , Metabolism , Lymph Nodes , Metabolism , Pathology , Lymphatic Metastasis , Pathology , Neoplasm Invasiveness
SELECTION OF CITATIONS
SEARCH DETAIL